Accident Report Detail
Accident Summary Nr: 14550578 - CRUSHED BETWEEN COUPLERS ON RAILROAD TANK CARS
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1586015 | 08/08/1984 | 2874 | 0 | Beker Industries Corporation |
Abstract: ON AUGUST 7, 1984, AT APPROXIMATELY 6:30 PM, EMPLOYEE #1, A BRAKEMAN, WAS SWITCHING RAIL CARS FOR WEIGHING. WHILE THE ELEVEN CAR TRAIN, WITH ENGINE, WAS IN MOTION EMPLOYEE #1 STEPPED BETWEEN THE SECOND AND THIRD CARS, SEPARATED THE COUPLERS AND TURNED OFF THE AIR BRAKE COCK ON THE THIRD CAR. HE THEN TOLD THE ENGINER TO SPEED UP. AS THE ENGINE THROUGH SECOND CAR ACCELERATED, THE AIR HOSE CONNECTION BETWEEN THE SECOND AND THIRD CARS WAS PULLED APART. BRAKE AIR PRESSURE THEN ESCAPED FROM THE BRAKE SYSTEMS OF THE ENGINE AND CARS 1 AND 2, ACTIVATING THE EMERGENCY BRAKING SYSTEM. AS THE ENGINE AND FIRST TWO CARS SLOWED DOWN, THE BRAKEMAN SAW HIS MISTAKE AND STEPPED BETWEEN CARS 2 AND 3 AGAIN TO RECTIFY THE PROBLEM. CARS 3 THROUGH 11, NOW ROLLING FASTER THAN THE ENGINE AND CARS 1 AND 2, STRUCK EMPLOYEE #1 AND CRUSHED HIM AGAINST THE STOPPED ENGINE AND CARS 1 AND 2.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1586015 | Fatality | Other | Occupation not reported |
Translate