Accident Report Detail
Accident Summary Nr: 134177.015 - One employee is killed and one is injured when crane basket
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1520787.015 | 03/22/2021 | 237130 | Mesa Line Services, Llc |
Abstract: At 12:25 a.m. on March 21, 2021, Employees #1 and #2 and a coworker, employed by a power and communication line construction company, were engaged in the construction of a power line tower. Employees #1 and #2 were working from a personnel basket hoisted by their coworker, a crane operator. They were installing the arms of a monopole. As they adjusted the bracket, the personnel basket, which was not properly secured to the crane boom, fell off the boom. Employees #1 and #2 fell with the personnel basket, a fall height of 150 feet. Employee #1 sustained blunt force trauma to the head and neck and was killed. Employee #2 was transported by emergency services to the hospital, where he was admitted for treatment of multiple injuries including multiple fractures and fluid in the lungs. The subsequent investigation of the equipment failure determined that the large retaining pin had not been inserted to keep the basket and jib attachment secured to to the jib adaptor and crane boom. In addition, no one had conducted visual inspections of the equipment.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Powerline, transmission line | New project or new addition | 150 | X | ||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 1520787.015 | 23 | M | Hospitalized injury | Electrical Power-Line | Distance of Fall: 150 feet Worker Height Above Ground/Floor: 150 feet Cause: Erecting structural steel Fatality Cause: |
|
| 2 | 1520787.015 | 29 | M | Fatality | Electrical Power-Line | Distance of Fall: 150 feet Worker Height Above Ground/Floor: 150 feet Cause: Erecting structural steel Fatality Cause: |