Accident Report Detail
Accident Summary Nr: 133975.015 - Employee incurs burns by molten asphalt during equipment ope
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1515807.015 | 02/18/2021 | 921190 | City Of North Las Vegas Public Works |
Abstract: At 2:18 p.m. on February 11, 2021, an employee was operating a Cimline crack sealing machine (model 230 DHC, serial #1C92M15248M119049) and looking down at the drain valve while releasing molten asphalt from the equipment's storage tank. Due to a miscommunication between management and employees, the operation was conducted without proper personal protective equipment (PPE). The employee was wearing only safety glasses and sustained second-degree burns to the face, arms, and hands. Required PPE for this task includes a full skin-covering garment, face shield, and gauntlet-style gloves. The employee was hospitalized for treatment.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Highway, road, street | Maintenance or repair | ||||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 1515807.015 | 33 | M | Hospitalized injury | Equipment Operator: Heavy | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Other Activities-Installing Ornamental And Archite Fatality Cause: |