Accident Report Detail
Accident Summary Nr: 122613.015 - Two employees are struck by crane boom extension arm as it f
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1451103.015 | 12/10/2019 | 811310 | Joel Klipping |
Abstract: At 2:15 p.m. on December 6, 2019, an employee was swinging an extension arm for a boom crane when it fell, striking two employees. Employee #1 was killed and Employee #2 was severely injured, hospitalizing him.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Other building | Maintenance or repair | X | |||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1451103.015 | 54 | M | Hospitalized injury | Millwrights | |
| 2 | 1451103.015 | 25 | M | Fatality | Millwrights |