Accident Report Detail
Accident Summary Nr: 117039.015 - Employee is electrocuted when truck mast touches power lines
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1407471.015 | 06/12/2019 | 237110 | Woofter Pump & Well, Inc. |
Abstract: At 1:45 p.m. on June 10, 2019, Employee #1, employed by a company that drills and services wells, was working at a residential job site and preparing to service the water well. He was raising the mast of the truck when the mast came into contact with overhead power lines. Employee #1 was electrocuted. He fell into the open pit containing the well. As he fell, he dislodged a pipe, causing the hole to fill with water.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Single family or duplex dwelling | Maintenance or repair | 12 | X | ||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Construction |
|---|---|---|---|---|---|---|
| 1 | 1407471.015 | 45 | M | Fatality | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Other Activities-Installing Ornamental And Archite Fatality Cause: |