Accident Summary Nr: 105529.015 - Employee is struck and killed by falling tree
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1315681.015 | 05/12/2018 | 113310 | Sweany Trucking And Hardwoods Llc |
Abstract: At 11:21 a.m. on May 12, 2018, Employee #1 was operating a Bobcat Skidsteer loader during logging operations. After tying one end of a rope to the Bobcat and the other end to a large tree, Employee #1 operated the Bobcat in the opposite direction of the tree. The tree fell, striking the Bobcat and Employee #1. Employee #1 suffered injury and was killed.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1315681.015 | 37 | M | Fatality | Equipment Operator: Skidsteer/Bobcat |