Accident Report Detail
Accident Summary Nr: 101442.015 - Employee falls with collapsing bucket elevator and is lacera
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1270862.015 | 10/16/2017 | 238290 | Specialty Industries Inc. |
Abstract: At 1:30 p.m. on October 14, 2017, Employee #1 and Coworker #1, employed by a crane services company, were working at a multiemployer construction project. They were at the top of a grain elevator and removing a deteriorated bucket elevator. The bucket elevator collapsed, and Employee #1 rode on the collapsing bucket conveyor as it fell 12 feet to the elevator platform. Employee #1 was caught and pinned between the platform's walkway railing and the collapsed bucket elevator. Emergency services were called, and Employee #1 was transported to the hospital. He was treated for a large laceration that extended around the left side of his torso from his back to his abdomen.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Tower, tank, storage elevator | Alteration or rehabilitation | 127 | |||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Construction |
|---|---|---|---|---|---|---|
| 1 | 1270862.015 | 30 | M | Hospitalized injury | Distance of Fall: 11 feet Worker Height Above Ground/Floor: 127 feet Cause: Temporary work (buildings, facilities) Fatality Cause: |